Spiral Laminar Flow: The Evidence

Section C: In Vivo Human Studies

1. Patterns of blood flow as a predictor of maturation of arteriovenous fistula for haemodialysis

J Vasc Access 2014;15 (3): 169-174
Yazin Marie1, Alison Guy1, Karen Tullett1, Hari Krishnan1, Robert G. Jones2, Nicholas G. Inston1
1 Department of Renal Surgery
2 Department of Interventional Radiology
Queen Elizabeth Hospital, University Hospitals Birmingham NHS Trust, Birmingham, UK

Purpose

A palpable “thrill” is traditionally associated with success following arteriovenous fistula (AVF) surgery. A thrill typically characterizes turbulent flow and this is a paradox as turbulence is a driver of neointimal hyperplasia. Spiral laminar flow (SLF) has been described as normal and protective pattern of flow in native arteries and is associated with superior patency in bypass grafts that generate it. The aim of this study was to define the pattern of flow within AVFs immediately post-operatively and at follow-up to assess maturation.

Methods

Doppler ultrasound was used immediately post-operatively and at follow-up (6 weeks). Blood flow was assessed as SLF or non-SLF. Two blinded qualified observers analysed the images. Patients were followed up for 6 months. Maturation was statistically analysed against the type of flow.

Results

Sequential patients having AVF surgery (n=56) were assessed: 46 (82%) patients had a thrill, 3 patients had no flow and 7 patients had pulsatile flow without a palpable thrill. SLF was present in 80% of those with a thrill but not in any without a thrill (p<0.0001). At follow-up (n=51) 41, patients had a matured AVF (80%), of which 76% had SLF immediately post-operatively. Only one patient with SLF failed to mature. In the non-SLF group 5 of the 15 AVFs failed to mature (66%; p<0.005).

Conclusions

SLF was strongly supportive of successful fistula maturation. A “thrill” was characteristic of spiral rather than turbulence. The mechanism of this apparent beneficial effect of this pattern of flow requires further investigation.

Back to top

2. The characteristic flow pattern of a “thrill” in Autologous AV Fistulae above the swing segment is spiral flow rather than turbulence

Presented at the Vascular Access for Haemodialysis XIII Symposium, May 9-11, 2012, Orlando, Florida, USA
Nick G. Inston, MD, Yazin Marie, Stephen J. Mallor, Hari Krishnan and Robert Jones

Objectives

In healthy individuals arterial blood flow has been characterized as having a spiral laminar pattern (Stonebridge P et al 1991). A loss of this pattern of flow is associated with pathology (Houston G et al 2004). It can be hypothesized that the effect of the spiral nature of flow is to maintain healthy physiologic levels of shear stress on endothelial cells. Pathological flow patterns and reduction of shear stress result in loss of atheroprotective mechanisms and promote pathology such as neointimal hyperplasia.
The desired characteristic of a successful AVF is a thrill typically associated with turbulent flow. The aim of this study was to characterize the nature of flow in autologous AVF and assess spiral flow specifically.

Methods

Using Doppler ultrasound both brachiobasilic and radiocephalic AVF were assessed in the peri-operative period for the characteristic flow patterns. AVFs were assessed immediately post operatively at the swing segment and 5cm above the swing segment in vein that had not been operated on.

Results

In patients with an immediate post-operative thrill (RCF n=10; BCF n=10) spiral flow was demonstrated within all fistulas in the vein above the swing segment. Within the swing segment flow was not spiral and had turbulent characteristics. The inflow artery in all cases demonstrated spiral flow.

Conclusion

The demonstration of spiral flow in the non-operated segment of AVFs has major implications. The low incidence of stenoses within this segment supports the hypothesis that spiral flow is atheroprotective whereas turbulent flow is pathological. In addition the demonstration of flow changing from spiral flow in the artery to turbulent in the swing section and then restoration of spiral flow in the vein supports the vein ultrastructure as the mediator of spiral flow. The impact of spiral flow on AVF maturation and function is currently under investigation.

Back to top

3. The Presence of Spiral Laminar Flow in Autologous Arterio-venous Fistulae

Poster at the Vascular Access Society of Britain and Ireland Symposium, September 2011, Brighton, UK
Guthrie, Suttie, Ross, Levison & Stonebridge

Purpose

In non-atherosclerotic vessels, flow is predominantly ‘spiral laminar’ rather than laminar. Spiral Laminar Flow (SLF) stabilises flow patterns at regions of arterial branching. Non SLF at stenotic segments results in poor flow cohesion, increasing turbulence. SLF has been shown to prevent the development of renal and carotid artery stenosis.
We aimed to determine if SLF is present in arterio-venous fistulae (AVF) and correlate this with flow limiting stenosis.

Methods

Patients attending routine duplex surveillance of their arterio-venous fistula for haemodialysis (September-November 2010), were assessed for SLF in the venous limb of their AVF. Data collected included: age; sex; type of AVF; primary AVF or not (fistula number); presence of flow limiting stenosis.

Results

We recruited 33 (15 male, 18 female) consecutive patients (mean age of 68 years, range 30-94 years). All AVF were autologous, 10/33 radiocephalic, 15/33 brachiocephalic and 8/33 brachiobasilic with superficialisation and all were being utilised for haemodialysis at time of surveillance. The majority were primary fistulae (24/33), seven being secondary and two being tertiary AVF. SLF was identified in 31 of the AVF, with 10 noted to a have non flow limiting stenosis. Age, fistula type and fistula number had no significant impact on stenosis formation. Due to only two AVF without SLF, association between stenosis, age, sex, AVF type and number with SLF was not conclusive.

Conclusion

Spiral Laminar Flow is present in autologous arterio-venous fistula with no flow limiting stenosis. We continue to collect data to determine if Spiral Laminar Flow affects patency and flow of arterio-venous fistulae.

Back to top

4. Three-dimensional blood flow dynamics: spiral/helical laminar flow

Methodist Debakey Cardiovasc J. 2011 Jan-Mar;7(1):21-6. Stonebridge P.

Recent work in cardiac and peripheral vascular blood flow has shown evidence for an elegant complexity to flow within the heart and in the large to medium arteries. Blood flow is normally described as laminar in that the blood travels smoothly or in regular paths. The velocity, pressure, and other flow properties at each point in the fluid remain constant, all parallel to each other. Our understanding has revolved around a two-dimensional representation of flow within three-dimensional blood vessels. However, MRI and colour Doppler flow imaging techniques have demonstrated that there is a spiral/helical/rotational property to laminar blood flow. The column of blood turns on a central axis as it passes along the major arteries.

Back to top

5. Spiral laminar flow in the abdominal aorta: a predictor of renal impairment deterioration in patients with renal artery stenosis?

Nephrol Dial Transplant. 2004 Jul;19(7):1786-91. Epub 2004 May 25
Houston JG, Gandy SJ, Milne W, Dick JB, Belch JJ, Stonebridge PA.
Tayside University Hospitals, Clinical Radiology, Dundee, UK. [email protected]

Background

Spiral or helical arterial blood flow patterns have been widely observed in both animals and humans. The absence of spiral flow has been associated with carotid arterial disease. The aim of this study was to detect the presence of aortic spiral flow using magnetic resonance imaging (MRI) and to evaluate the relationship of the presence of spiral aortic flow with renal arterial disease and renal function in the follow-up of patients with suspected renal atheromatous disease.

Methods

Prospective study of 100 patients with suspected renal arterial disease and 44 patient controls. Using a 1.5 T MRI unit (Siemens Symphony), phase contrast flow quantification and three-dimensional contrast enhanced MR angiography of the abdominal aorta were performed. Renal arterial stenoses (RAS) were classified minimal, moderate or severe. Renal function was followed at 3 months before and 6 months after MRI. RESULTS: Non-spiral flow was more prevalent in patients with more severe RAS. Renal impairment progressed significantly in severe RAS without spiral flow (P = 0.0065), but did not progress significantly in severe RAS with spiral flow (P = 0.12). In minimal or moderate RAS with or without spiral flow there was no significant progression (P = 0.16, 0.13, 0.47, 0.092, respectively).

Conclusion

Aortic spiral blood flow can be assessed with MRI. Lack of aortic spiral blood flow in patients with severe RAS is associated with significant short-term renal function deterioration. Determination of blood flow patterns may be a useful indicator of renal impairment progression in patients with suspected renal artery stenosis.

Back to top

6. Two-dimensional flow quantitative MRI of aortic arch blood flow patterns: Effect of age, sex, and presence of carotid atheromatous disease on prevalence of spiral blood flow

J Magn Reson Imaging. 2003 Aug;18(2):169-74.
Houston JG, Gandy SJ, Sheppard DG, Dick JB, Belch JJ, Stonebridge PA.
Department of Clinical Radiology, Ninewells Hospital and Medical School, Tayside University Hospitals NHS Trust, Dundee, Scotland, UK. [email protected]

Purpose

To determine the effect of age, sex, and presence of carotid atheromatous disease on the presence of aortic spiral blood flow pattern using two-dimensional flow quantitative magnetic resonance imaging (MRI).

Materials & Methods

Sixty subjects (37 women, 23 men) were examined. Prospective phase contrast flow quantitative MRI (1.5 T, Siemens Symphony) sequences in the plane of the aortic arch, and three-dimensional contrast-enhanced MR angiography of the vessels from the aortic arch to the circle of Willis, were performed. Flow quantitative analysis, using circular regions of interest, in the root, apex, and descending aortic arch to determine the presence of a spiral blood flow pattern was undertaken. The results were correlated with the subjects age, sex, and presence of significant carotid arterial disease.

Results

A spiral blood flow pattern was seen during diastole in 43 of 50 (86%), 42 of 48 (88%), and in 26 of 28 (93%) subjects in the root, apex, and descending aortic arch, respectively. Spiral flow was seen during systole in 14 of 35 (40%), 20 of 47 (42%), and 11 of 31 (35%) subjects in the root, apex, and descending aortic arch, respectively. There was no clear effect of age or sex on the presence of spiral flow. Carotid disease was associated with a significant reduction in the prevalence of systolic spiral flow from 51%-19% subjects (P < 0.05).

Conclusion

Spiral flow pattern can be seen in the arch of the aorta in clinical practice using flow quantitative MRI. The prevalence of spiral flow pattern does not appear affected by subject age or sex. Carotid atheromatous disease is associated with a reduction in prevalence of systolic spiral flow pattern in the aortic arch.

Back to top

7. 4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects

J Magn Reson Imaging. 1999 Nov;10(5):861-9. Bogren HG, Buonocore MH.

Abstract

Four-dimensional magnetic resonance MR velocity mapping was developed to study normal flow patterns in the thoracic aorta using time-resolved cardiac gated three-directional velocity data. Sixteen normal subjects were studied, one young group (average age 31 years) and one group with elderly people (average age 72 years). Blood flowed in a right-handed helix from the ascending aorta to the aortic arch. A straight flow pattern or a left-handed helix was seen in the descending aorta. Blood flow was never parabolic. Blood flowed forward in early systole, retrograde in mid-to-end systole, and forward again in diastole in all subjects as a basic pattern. Continuous retrograde flow over a long distance was not seen, but blood entered a retrograde flow column at various levels. In young people blood passed from the aortic valve to the mid-descending aorta in less than one heartbeat. In people in their sixties it took two heartbeats and in people older than 78 years, it took three heartbeats. The maximum systolic forward velocities were higher in young subjects than in elderly while the retrograde velocities were lower.

Back to top

8. Spiral laminar flow in vivo

Clin Sci (Lond). 1996 Jul;91(1):17-21.
Stonebridge PA, Hoskins PR, Allan PL, Belch JF.
Department of Surgery and Medicine, Ninewells Hospital, Dundee, U.K.

Blood flow patterns are poorly understood despite their impact on arterial disease. There have been few measurements in vivo of the three-dimensional blood flow patterns; we present the results of such studies using a new non-invasive in vivo method of examining biplanar arterial blood flow patterns.
Multiple colour Doppler ultrasound directional velocity images were obtained at two different beam target angles from the artery in the plane perpendicular to its axis. Ensemble average images were constructed; the absolute velocity and direction were calculated by compounding the left and right averaged images. Simple directional, non-directional velocity and vector maps were constructed.
Flow patterns were sampled in 11 healthy male volunteers at four points of the pulse cycle; peak systole, systolic downswing, diastolic reverse flow and diastolic forward flow and at three sites; the right common and distal superficial femoral and the left common femoral arteries.
Stable rotational flow was observed in all subjects, the direction of rotation varying between sides and individuals.
There are theoretical advantages to spiral laminar blood flow; the forward-directed, rotationally induced stability and reduction of laterally directed forces may reduce turbulence in the tapering branching arterial tree and at stenoses and have a beneficial effect on mechanisms of endothelial damage and repair.

Back to top

9. Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping

Circulation. 1993 Nov;88(5 Pt 1):2235-47. Kilner PJ, Yang GZ, Mohiaddin RH, Firmin DN, Longmore DB.

Background

Helical and retrograde secondary flows have been recorded in the aorta, but their origins and movements in relation to the arch have not been clarified. We set out to do this using magnetic resonance velocity mapping.

Methods & Results

Three-directional phase contrast cine magnetic resonance velocity mapping was used to map multidirectional flow velocities in the aortas of 10 healthy volunteers. Computer processing was used to visualize flow vector patterns in selected planes. Right-handed helical flows predominated in the upper aortic arch in late systole, being clearly recognizable in 9 of the 10 subjects. Non-axial components of velocity in this region reached 0.29 m/s (+/- 0.05 m/s) as axial velocities declined from a peak of 1.0 m/s (+/- 0.1 m/s). Helical flow patterns in the upper descending aorta varied between subjects, apparently depending on arch curvature. End-systolic retrograde flow originated from regions of blood with low momentum, usually along inner wall curvatures. Flow studies in a curved tubular phantom showed right-handed helical flow in the upper “arch” when the inflow section was positioned to simulate ascending aortic curvature, and retrograde flow occurred along the inner wall at end systole during pulsatile flow.

Conclusion

Helical and retrograde streams are consistent features of intra-aortic flow in healthy subjects that result, at least in part, from the curvature of the arch and the pulsatility of flow in it. They may have significance in relation to circulatory dynamics and the pathogenesis of atheroma in the arch.

Back to top

10. Spiral laminar flow in arteries?

Lancet. 1991 Nov 30;338(8779):1360-1.
Stonebridge PA, Brophy CM.
Vascular Surgery Unit, Royal Infirmary, Edinburgh, UK.

Spiral blood-flow patterns in infrainguinal blood-vessels were observed at angioscopy in 54 patients who underwent peripheral vascular reconstruction; the endoluminal surface had spiral folds in 51 of 75 arteries examined. Spiral flow patterns, congruous with inherent endoluminal anatomical features, might more accurately represent blood-flow in infrainguinal arteries than current models of laminar flow.

Back to top

To find out how Vascular Flow can assist you in your new development project, get in touch today.

Craig Dunlop, General Manager, Vascular Flow Technologies

General Manager

Craig Dunlop

Craig joined Vascular Flow in May 2014.  He comes with over 20 years of industry experience as a medical device engineer and manager.  Most recent positions held were at Vascutek Ltd as OEM Technical Manager and Development and Operations Manager for ePTFE Products.
Craig has a broad portfolio of successful new product developments and introductions within the Cardiovascular arena and has worked in both Europe and USA.
Craig was educated in Engineering and Operations Management at University of West of Scotland.

Kate Full at Vascular Flow Technologies

Financial Controller

Kate Full

Kate joined Vascular Flow Technologies from Braveheart Ventures where she was responsible for the evaluation and development of investment opportunities, focusing on financial diligence.
A Chartered Certified Accountant, she trained with PriceWaterhouseCoopers, qualifying in 2001 and continued in professional practice until joining Braveheart in 2004. Prior to embarking on her professional training Kate held a number of different accounting roles in a variety of industries including manufacturing, wholesale and leisure.

Angela Paterson, Head of QA & Regulatory Affairs, Vascular Flow Technologies

Head of Quality Assurance & Regulatory affairs

Angela Paterson

Angela joined Vascular Flow Technologies in April 2013 after spending the previous 14 years in Quality Assurance within a vascular graft manufacturing environment. Prior to this she spent three years in laboratories/ Biotech. Angela also has extensive experience working with regulatory agencies e.g. US FDA and Japanese PMDA.
Angela has a BSc in Applied Biosciences from Glasgow Caledonian University.

Jim Veitch, Head of Global Business Development, Vascular Flow Technologies

Head of Global Business Development

Jim Veitch

Jim has over 2 decades of experience in the Global Medical Device Business with a special interest in cardiovascular, LVAD, TAH and dialysis disease areas.
He works with numerous large and small device companies assisting in the successful promotion and commercialisation of their novel technologies.
This experience will help guide Vascular Flow through the next stages of their development and global expansion.

Graeme Houston, Non-Executive Director, Vascular Flow Technologies

Non-executive Medical Director

Graeme Houston

As Chair of Clinical Imaging and Intervention, University of Dundee, Professor Houston is a Consultant Cardiovascular Radiologist with an interest in endo-vascular therapies, and non-invasive vascular imaging using MRI and Ultrasound.
His medical training at St. Thomas’s Hospital in London followed first class honours science degrees in physics and pathology at Cambridge University.
His endo-vascular training was undertaken initially in Glasgow and further developed as a Fellow at the University of British Columbia, Vancouver, Canada. He is responsible for intellectual property, and as Medical Director is responsible for the clinical scientific research in the Spiral Laminar Flow™ field and stent technology.

Medical Device Development

Become an Investor

We are always interested to hear from potential investors with a view to accelerating our ambitious business plan and global reach or hearing from potential partners with a view to developing our Spiral Flow Technology in other areas.
If you want to find out more about investment opportunities in Vascular Flow Technologies, you can contact us directly on +44 1382 598 532.

Contact us
Medical device ISO class 7 clean room services

ISO Class 7 Clean Room

The Vascular Flow ISO Class 7 rooms provide air cleanliness of a maximum of 352,000 particles per cubic meter at 0.5μm and 60 to 90 air changes per hour. Vascular Flow use this cleanroom environment for medical device manufacturing and packaging processes.  Each client has dedicated cleanroom space and time.

Medical device Contract assembly services

Contract Assembly Services

Vascular Flow provide medical device contract assembly services to successfully deliver to our clients specifications. We assemble a wide range of medical devices for the world’s leading companies at low and medium volume manufacturing scales in our ISO Class 7 cleanroom environment.
Contact us today to find out how we can help you with your medical device contract assembly needs.

Medical device contract packaging services

Contract Packaging Services

Vascular Flow offer innovative packaging solutions for your medical device. Our ISO Class 7 cleanroom processes ensure 100% product or customer specific isolation to avoid contamination
We are specialists in low volume medical device contract packing projects for small and medium sized organisations. Our packaging solutions are optimised for process reliability to ensure consistent on time and on budget.
Contact us today to find out how we can help you with your medical device contract packaging needs.

injection moulding services

Injection Moulding Services

Our recognised know-how in plastic injection moulding enables Vascular Flow to offer our clients comprehensive and customised support, from the design of their devices right through to production, all in accordance with international regulatory requirements (ISO 13485-2016, ISO 15378 and QSR – 21 CFR part 820).

Medical device label printing services

Medical Device Label Printing Services

Vascular Flow Technologies are here to help get your products noticed. Our team is motivated to see your product succeed, whether you need a hundred labels or thousands of labels applied every day, we can meet your demand. Vascular Flow work with you to ensure only adhesives and topcoats that are compatible with your sterilization process are used.

Computer Aided design Services

Computer Aided Design Services

Vascular Flow utilises the latest Solidworks 3D CAD software to compliment its R&D offering.
Our highly skilled technical team utilises CAD to create and improve designs and reduce costs and is key to good communication of new products and documenting design history. We also have experience in parametric design processes and non-linear/complex curvature model creation.

Dummy Image

Finite Element Analysis

The team of experts at Vascular Flow can predict the structural performance of medical devices in conjunction with biological tissues using Finite Element Analysis (FEA).
Out team can couple together different physical effects using FEA, including heat and mass transfer, chemistry, fluid flow, electricity and solid mechanics.
We direct FEA to accelerate pace of innovation, decrease clinical trial costs, mitigate design risks and streamline the approval process.
Computational models are used to obtain information that are either too challenging or impossible to be obtained experimentally in pre-clinical or clinical studies.
To find out how Vascular Flow can assist you in your new development project, get in touch today.

In Vitro Flow Services (Bench Models)

In Vitro Flow Services (Bench Models)

In vitro tests with a bespoke, computer-controlled flow rig are used to verify the outcomes of medical devices in a controlled environment.
Vascular Flow has the capability of producing complex geometries and pulsatile flow to represent medical devices in blood vessels. We measure flow rates with pressure and flow sensors, and complex flow structures are measured with Doppler ultrasound. Blood viscosity and density are reproduced with blood mimic fluid.
In vitro flow & deployment (Cadaveric models)
Cadaveric models are the most realistic anatomical models to test vascular devices prior to pre-clinical trials.
Vascular Flow work in partnership with the University of Dundee and Tayside Health Board to test the deployment and flow outcome of vascular devices in a cadaveric anatomical model. The cadaveric bodies using the Thiel soft-fix method, which preserves them with life-like flexibility and tissue quality. Flow and anatomy are visualised with ultrasound, fluoroscopy, CT or MRI.

Project- Management and Delivery Services

Project Management & Delivery Services

Vascular Flow Technologies highly experienced team has a proven track record of taking products from initial design concept to market.
All projects delivered by Vascular Flow are ISO13485 compliant with Design History File generation.
We can work in collaborative partnerships or provide full turn-key solutions, offering flexible design, development & verification costing models.

Prototyping & Testing Services

Prototyping & Testing Services

To assist our clients to rapidly get their products to market, we offer a range of rapid prototyping services including injection moulding and plasma treatment.
We have vacuum chambers, furnaces with gas retort and laminar flow and extraction cabinets to allow us to safely and effectively work with your device design.
The product testing services we offer our clients are numerous and include:
· Burst testing
· Tensile testing
· Compression testing
· Suture retention testing
· Repeat puncture testing
· Permeability testing
· Package peel testing
· Dimensional testing
· Kink testing
· Flow testing
· Ultrasound doppler analysis
Our research team are highly adaptable and will work with you hand in hand to get the job done and move your project forward at pace.

Dummy Image

Regulatory Support

Vascular Flow Technologies has extensive Class IIa, IIb, III device submission experience with both CE and 510k submissions and approvals.
We can support full ISO 13485 design history and technical file generation & ISO14971 Risk Assessment.
Our experienced team can undertake full Clinical Literature Reviews on your behalf to support the early-stage feasibility processes.

Medical Device Development Services ISO Standard Performance Testing Services

ISO Standard Performance Testing Services

Vascular Flow has invested heavily in equipment and enhanced its laboratory to capitalise on the in house experience gained through previous projects and taking products to market.
This expertise allows us to offer product performance testing to ISO 7198 (Cardiovascular implants and extracorporeal systems) and ISO 10555 (Intravascular catheters).
Working within the constraints of our quality system ensures customers always receive comprehensive reports and test results.

Lucy Petersen, QA & RA Manager, Vascular Flow Technologies

QA & RA Manager

Lucy Petersen

Lucy joined Vascular Flow Technologies in January 2020 bringing with her knowledge and experience in quality and research and development gained in medical device manufacturing. Lucy also has experience in biocompatibility and toxicology as well as working with regulatory agencies e.g US FDA.
Lucy has a BSc in Chemistry from Aberdeen University.

Privacy Preferences

When you visit our website, it may store information through your browser from specific services, usually in the form of cookies. Here you can change your Privacy preferences. It is worth noting that blocking some types of cookies may impact your experience on our website and the services we are able to offer.

For performance and security reasons we use Cloudflare
required
Our website uses cookies, mainly from 3rd party services. Define your Privacy Preferences and/or agree to our use of cookies.